Table 1 — This
table shows the range of values assignable to various lamp types.
| Aspect |
Vacuum
Lamps |
Gas
Filled &
Halogen Lamps |
| Color
Temperature degK |
1800-2600
|
2200-3200 |
| Efficiency,
Candle Power/Watt |
.1-.7
|
.2-2.2 |
| Filament
Current, Amperes |
.01-.40
|
.35-10 |
| Filament
Voltage |
1.0-32
|
2.5-28 |
| Max.
Allowable Ambient Temp |
100C
|
250C |
| Bulb
Skin Temp, Approx. Average |
60C |
300C |
| Filament
Rise Time, Sec. |
.005-.1
|
.1-1 |
| Lifetime
Average Hours AC |
250-25,000
|
20-10,000 |
| Lens
End Foot Candles |
100-2000
|
500-40,000 |
Nomograph (Approximate)
— This table shows the changes in values of various lamp properties as a
result of input voltage increase or decrease.
For instance,
a 5 volt lamp run at 6 volts (6/5=1.2) would have an approximate candlepower
of 1.9X, a life of .1X and a current of 1.1X when compared to it's 5 volt
rating.
Graph
1 —
This graph shows typical lamp envelope transmissions curves. This
curve is useful in the employment of lamps as visual or Infra
Red Sources. Also consider the use of one of our reflectors to
further concentrate energy levels and to control light projection. |
 |
Graph
2 —
This graph shows the transmission of Sapphire and Zinc Selenide windows
that are used in Carley Lamps Infra Red Sources. |
 |
Illustration
1 —
Illustration one features popular lamps produced by Carley technicians.
|
 |
1.
Tipped Halogen C6 filament 2. Lens end Halogen Lamps with C2R filament
and stiff pin leads. 3. Non Lens, Wire Lead, Xenon gas Filled Lamp. 4.
Non Lens end lamp with C2R filament in a flange base. 5. Tipped Halogen
Lamp with C6 filament in a PR base. 6. Non Lens end lamp with frosted
glass, stiff pin leads with C2R filament. 7. Non Lens end lamp with C2R
filament and Insulated lead extensions 8. Non Lens end lamp with C2R filament
and Nickel lead extensions welded on at glass seal.
NOTE:
Most
lamps can be built in a TL lens end or a T non lens end glass envelope.
Lamp leads or leg's can be cut or un-cut. Please specify if you require
your lamp leads cut to a specific length. Contact Carley
Lamps for more information and to discuss your unique application.
|